Cargador CDR-5000.


CDR-5000 Battery Charger
A breakthrough in charger technology!

So easy to use and program, and so accurate and versatile, the CDR-5000 is the "must-have" charger for today's demanding modeler!

a.. Charges, discharges and cycles transmitter and receiver packs without removing them from the radio.
b.. Auto cut-off can be programmed for delta peaking, mAh and temperature settings.
c.. Five built-in fans provide maximum cooling.
d.. Also features reverse polarity and overload protection.
e.. Linear current charger with advanced peak detection and automatic cutoff circuit with MOSFET.
f.. State of the art Charger/Discharger/Cycle NiCD/NiMH TX, RX, DX
g.. Large LCD display (192 x 128 dot graphic) with backlight.
h.. Users name (up to 8 characters) can be programmed in.
i.. TX/RX/DX set up is capable of memorizing 10 types of charging/discharging data information.
j.. LEDS- Red is for charging, Blue is for discharging.

Unit includes the following:

a.. TX Charge adapter- used to charge and discharge batteries for transmitters.
b.. RX Charge adapter- used to charge and discharge batteries for receivers.
c.. Terminal Harness- used for measuring characteristics of each cell in a serially composed battery. (2-6 cells)
d.. Conversion table- to help convert Celsius temperatures to Fahrenheit temperatures.
e.. Input clips- to connect to a power source.
f.. Thermo sensor- Sensor for batteries that are monitored and battery characteristic during charging and discharging at a certain level.
g.. Output clips- for connection to DX batteries.
h.. Charger stand
i.. TX/RX charge adapter terminal.
j.. Terminal harness connector.
k.. Thermo stand connector. (Thermo stand sold as optional)
l.. Printer connector. (For factory use only)
m.. PC connector (For factory use only)

DX Set up
a.. Set Charge- Set charging current from .01 to 12A (in .01A increments)
b.. Set Discharge- Set the discharging current from .1 to 40A (in .01A increments)
c.. Cycle Mode- set the number of cycles for charging and discharging. Capable of cycling from 1 to 99 times.
d.. Charge Cut-off Delta Voltage- set the voltage for "Delta Peak" detection level (ODV or 3-5mV/cell in 1mV/Cell increments)
e.. Charge Cut-off Temperature- maximum temperature of the battery. Setting range from 25 to 75 degrees Celsius in 1 degree increments.
f.. Charge Cut-off Max Voltage- The maximum voltage of the battery. Setting range from .1 to 62V in .001V increments.
g.. Charge Cut-off Capacity- Set the maximum capacity. Setting range is from 50 to 9999mAh in 1mAh increments.
h.. Discharge Cut-off Volts- set the voltage of the battery for discharging. Setting range is from .1 to 62V in .001V increments, or can be set up with .8V/cell, .85V/cell or .9V/cell.
i.. Discharge Cut-off Time- to set the time to stop discharging. Setting range is from 10 seconds to 999m00 seconds in 1 second increments.
j.. Cell Numbers- to set the number of cells that are connected. 1-36 cells in 1 cell increments.

TX/RX Set up
a.. Set Charge- set the charging current for TX/RX. Setting range is from .05 to 2A in .01A increments.
b.. Set Discharge- set to discharge TX/RX. Setting range is from .1 to 5A in .01 increments.
c.. Cycle Mode- Set the number of cycle times for charging/discharging. Setting is from 1 to 99 cycles.

DX Data Screen
a.. Volts- shows the current battery voltage.
b.. Amperage- shows the present charging current or discharge current.
c.. Peak Volts- shows the peak voltage of a battery while the battery is charged.
d.. Average Volts- shows the average voltage of the battery while the battery is charged or discharged.
e.. First stage- shows the estimated average voltage at the early stage of discharging.
f.. Middle stage- shows the estimated average voltage at the middle stage of discharging.
g.. Last stage- shows the estimated average voltage of a battery a the last stage of discharging.
h.. Internal relative resistance- Shows the internal resistance of the battery under charging or discharging.
i.. Battery Capacity- shows the accumulated amount of charge or discharge from the beginning.
j.. Time- shows the accumulated amount of time from start of charging or discharging.
k.. Power level- the status of the battery under charging or discharging.
l.. Matched level- shows the matched level among the battery cells and how the cells are well matched to each other.
m.. Outside temperature- shows the temperature measured by the Thermo Sensor utilized in the CDR-5000.
n.. Humidity- Show the humidity around the CDR-5000.
o.. Battery temperature- shows the temperature measured by the Thermo Sensor or the Thermo Stand.
p.. Input voltage- shows the voltage of the power source.
q.. Set Amperage- shows the current preset for charging or discharging.
r.. Cut-off Voltage- shows the voltage to stop charging or discharging.
s.. Peak Voltage- shows the peak voltage of the battery while charging.
t.. Average Voltage- shows the average voltage while charging or discharging.
u.. Average Battery Temperature- shows the average temperature of the battery measured from the thermo sensor or the Thermo stand.

TX/RX Data Screen
a.. Mode- Indicates the condition of the battery.
b.. Volts- shows the current battery voltage.
c.. Amperage- shows the present charging current or discharge current.
d.. Peak Volts- shows the peak voltage of a battery while the battery is charged.
e.. Battery Capacity- shows the accumulated amount of charge or discharge from the beginning.
f.. Set Amperage- shows the current preset for charging or discharging.

Graphs
Plotting graphs

a.. Can show the relationship between the charging time, battery voltage, and temperature for 1 to 36 cells.
b.. Can also show the relationship between discharging time, battery voltage, and temperature for 1 to 36 cells.
c.. Can also show the relationship between the charging time and the cell voltage. (not applicable to a battery of 7 cells or more.)
d.. Also can show the relationship between the discharging time and the cell voltage.


Bar Graphs

a.. Shows the average voltages of each cell in the charging mode.
b.. Can show the peak voltages of each cell in charging mode.
c.. Can also show the average voltages of each cell in discharging mode.


Terminal Harness Graph
a.. Shows the voltage of each individual cell.

Environment Graphs
a.. These will show the temperature and the humidity measured by the Thermo Sensor built into the CDR-5000.

Input
a.. DC11-16V, Minimum 40Ah (low power voltage power-off @ 10V)

Cell Counts
DX Port 1-36 cells, NiCD/NiMH batteries, capacity 50-9999 mAh
TX & RX output Port 1-8 cells, NiCD/NiMH batteries, capacity 50-2500 mAh

Charging Current Limits
DX output 18V or less 12A Max (Increments of .01A)
27V or less 8A Max (Increments of .01A)
36V or less 6A Max (Increments of .01A)
45V or less 5A Max (Increments of .01A)
54V or less 4A Max (Increments of .01A)
62V or less 3A Max (Increments of .01A)
TX & RX output   0.05-2A (0.01A increments)

Discharging Current Limit
DX output 2.4V or less smaller than 40A (Increments of .01A)
7.5V or less 40A Max (Increments of .01A)
8.5V or less 35A Max (Increments of .01A)
10V or less 30A Max (Increments of .01A)
12V or less 25A Max (Increments of .01A)
15V or less 20A Max (Increments of .01A)
20V or less 15A Max (Increments of .01A)
30V or less 10A Max (Increments of .01A)
40V or less 7.5A Max (Increments of .01A)
50V or less 6A Max (Increments of .01A)
60V or less 5A Max (Increments of .01A)
Greater than 60V 4A Max (Increments of .01A)
TX & RX output 10V or less .1 to 5A Max (Increments of .01A)
Greater than 10V .1 to 3A Max (Increments of .01A)


Reference

Temperature Termination Temperature controlled automatic charge termination, variable in the range 25-75 degrees Celsius (1 degree Celsius increments, optionally for external temperature and/or thermo stand)

Voltage Termination Final charge voltage controlled automatic charge termination, variable in the range .1-62V (.001V increments) for lead-acid batteries.

Capacity termination Battery controlled automatic charge termination, variable in the range 50-9999 mAh

Final discharge Voltage Final discharge voltage controlled automatic discharge termination, variable in the range .1-62.0V (.001V increments)

Discharge Time Time controlled automatic discharge termination, variable in the range 10 seconds-999 minutes: can be switched off to allow deliberate deep discharge.

TX & RX output Digital Delta- Peak performance charge termination with automatic battery type detection (NiCD / NiMH): Delta Peak sensitivity automatically matched to battery type.

Cycle interval Switchable temperature-controlled cycle interval to protect batteries from overheating; applies to charge / discharge and discharge / charge cycle process.

Battery temp. measurement General battery temperature measurements in the range 5-99 degrees Celsius.

Humidity measurement internal humidity measurement in the range 20-95% relative humidity, permits accurate calibration of the charger.

Discharge-cut methods Detection by voltage: .8V/cell, .85V/cell, .9V/cell

Detection by time: 10 to 59940 seconds (999 minutes)

Power Consumption Less than 8W at 12V (at idle)

Operating Temperature 5 to 40 degrees Celsius

Storage Temperatures -20 to 60 degrees Celsius

Dimensions 170X170X83 mm

Weight 1200 g